Fully Tested Impact Resistant Curtain
Wall Systems to Accommodate 9/16″ Laminated Glass
Series PW256 is a 2-1/2” x 6-9/16” impact-resistant screw-spline assembled curtain wall system can accommodate 9/16” laminated glass designed for wind-borne debris applications. PW256 impact-resistant curtain wall is fully tested in accordance with ASTM and Florida Building Code standards for large missile impact and is approved for use in south Florida’s High Velocity Hurricane Zone and coastal areas considered wind-borne debris regions. PW256 options include fully captured and two-sided silicone structural glazed applications.
Hurricane Resistant Curtain Wall Features
Glazing gaskets:
Wet glazed with EPDM gasket on exterior
Dry glazed with EPDM gaskets interior and exterior utilizing Sentry Glass Plus laminates
Screw spline joinery allows:
Coral Punch Die shop fabrication
Die set punches spline and pressure bar weep holes
Panelized frame assembly for easy transporting and installation
Pressure Bars:
Preloaded with a dense EPDM thermal isolator at factory with attachment holes pre-punched 9″ O.C.
Attached to back members with #12-14 x 1 ¼” HWH #3 self-drilling screws
Removable snap-on interior trim covers at all horizontals allows:
Anchor inspection to substrate after glazing
Inspection and/or repair of critical joint seal areas after glazing
Injection molded plastic end dams and bridges at horizontals provides:
Accurate and tight seals at intersection of vertical/horizontal joints
Zone glazed system with weep holes for water control
Weep holes
Injection molded plastic top and bottom vertical mullion caps:
Accurate compression fit
Provides continuous perimeter seal
Injection molded plastic temporary glazing retainer:
Reduces labor
Distributes uniform pressure on glass reducing risk of breaking glass
Reusable for next project
Performance Test Standards
ASTM E 283 – Air Infiltration Test
STM E 331 – Water Infiltration Test
ASTM E 330 – Uniform Load Deflection and Structural Test
PW256 Hurricane Resistant Curtain Wall – ASTM E 1886-1996 – Missile Impact and Cycling Test
PW256 Hurricane Resistant Curtain Wall – Florida Product Approval Number – FL12880 (impact-resistant for use outside HVHZ)
Test standards in compliance with the 2014 Florida Building Code for applications outside HVHZ.